Turbidity Meters
Phase Separation ITM-3
Standard applications
- Phase separation of products (for example whey - cream - milk)
- Yeast harvest in breweries
- Leackage control of filter and gaskets
- CIP-return line (monitoring of pre-rinse water to product leftovers)

Advantages
- Patented, front flush sensor
- Independent to refl exions at small diameters or electro-polished surfaces
- 100% compatible to antecessor ITM-2, mechanical and electrical
- No color dependency (wave length 860 nm)
- Smallest pipe diameter: DN 25
- Four measurement ranges, two externally switchable
- High reproducibility: ≤ 1% of full scale
- Switching output (switchpoint and hysteresis free adjustable)
- Analog output 4...20 mA (standard)
High-Precision Turbidity Measurement ITM-4
Standard applications
- Monitoring product quality
- Fresh water monitoring in the beverage industry
- Process controls in beer brewing
- Monitoring water/waste water e.g. dairies, breweries, etc.)
- Monitoring filtrates
- Phase-separation of slightly turbid media

Advantages
- Extremely compact design suitable to pipe-diameters as of DN 40
- Fast response time
- Inductive, no-wear measurement method
- Analog temperature output
- Protection rating: IP 69 K
- CIP / SIP capable 140 °C / 30 min
- Product contact surface made of: PEEK
- External control input to select measuring ranges with various temperature coefficients